ZH1500

Disconnecting and earthing device

Description

The equipment is designed for all UIC voltages, from 1 kV AC up to 3 kV DC.
The equipment usually is built in behind a door und connected to that door via a rod. Opening of the door pulls the rod and disconnects the connection between the train bus bar and the power supply. The power supply is then connected to ground to allow safe access to the switch gear. This grounded state may be secured with up to 3 locks to prevent a second person to unintentionally connect the power supply again.
The contact system is designed for switching without load but allows some emergency switchings. Under normal operating conditions the main contactor "energy" is being switched off prior to the opening of the contacts via a door switch.

Features

  • Design according to all current safety standards
  • Insulation up to 5 kV according to current requirements
  • Standardised equipment, short lead timesv
  • Side or bottom installation, horizontal or vertical
  • Visable disconnection of power
  • 50124-1, EN50153, EN 50155
  • UIC 550-1, UIC 550-2, UIC 552

Technical Data

Operating voltage according to UIC 550 1.000 V AC ... 3.000 V DC
Insulation 5 kV
Dimensions 425 x 410 x 133 mm
Maximum current at 1.000 V AC, 16,7 Hz 150A
Maximum current at 1.500 V AC, 50 Hz 100 A
Maximum current at 1.500 V DC 100 A
Maximum current at 3.000 V DC 50 A
Maximum current at 5.000 V DC 50 A
Life time > 10,000 swtching cycles
Protection degree IP00
Temperature range -40°C ... +85°C
 

 

More information

 

Features

 
 
© 2007. Schaltbau GmbH