CVB25
Vacuum circuit breaker
The CVB Series vacuum circuit breaker is the main electrical switch and protection device of AC locomotives and electric multiple units.
Mode of operation: The energy required to switch on the CVB is stored by a spring. It takes only a small pulse energy to unlock the main spring release latch and set free the stored energy. As soon as the supply voltage is applied, the spring gets recharged in less than 10 s. When no control voltage is being applied, the vacuum circuit breaker is in switched off position and the spring remains charged and ready for the next switching operation.
Features:
• Electrically driven vacuum circuit breaker
• No secondary supply energy like pressurized air required
• Versions for 25 kV to UIC 550 available
• Following the fail safe principle
Application:
• AC main switch in electric locomotives and EMUs
Standards:
• IEC 60077-4, EN 50124-1, IEC 60694, EN 50155, EN 50121-3-2
Ordering code
- CVB25 AC vacuum circuit breaker
Technical Data
| Nominal voltage UN |
25 kV AC, 50/60 Hz
|
| Pollution degree |
PD4
|
| Overvoltatge category |
OV4
|
| Rated operating voltage Ue |
30 kV AC
|
| Rated operating current Ie |
450 A
|
| Short circuit breaking capacity |
20 kA
|
| Operating frequency |
C3
|
| Control voltage Ucontrol |
24 / 110 V DC
|
| Operating temperature range |
-40°C ... +70°C
|
|
|
More information
Features
|